Operating instructions
Digital angle gauge
Item no. 1662855
Intended use
The product is designed to measure angles between suitable surfaces. Measurements are
displayed on the LCD display. The angle gauge is powered by two AAA batteries. The product
is water resistant to IP54. It is suitable for outdoor use but must not be submerged under water.
For safety and approval purposes, you must not rebuild and/or modify this product. Using
the product for purposes other than those described above may damage the components. In
addition, improper use can cause hazards such as a short circuit, fire or electric shock. Read
the instructions carefully and store them in a safe place. Only make this product available to
third parties together with its operating instructions.
This product complies with statutory national and European regulations. All company and
product names are trademarks of their respective owners. All rights reserved.
Package contents
• Angle gauge
• Storage pouch
• Operating instructions
Up-to-date operating instructions
To download the latest operating instructions, visit www.conrad.com/downloads or scan the QR
code on this page. Follow the instructions on the website.
Explanation of symbols
The symbol with the lightning in a triangle indicates that there is a risk to your health,
e.g. due to an electric shock.
The symbol with an exclamation mark in a triangle is used to highlight important
information in these operating instructions. Always read this information carefully.
The arrow symbol indicates special information and advice on how to use the
product.
Safety information
Read the operating instructions and safety information carefully. If you do not follow the
safety information and information on proper handling in these operating instructions,
we will assume no liability for any resulting personal injury or damage to property. Such
cases will invalidate the warranty/guarantee.
a) General information
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly, as it may become a
dangerous toy for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, stop using it and prevent
unauthorised use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stress.
• Always handle the product carefully. Jolts, impacts or a fall even from a low height
may damage the product.
• Consult a technician if you are not sure how to use or connect the product.
• Maintenance, modifications and repairs must be done by a technician or a
specialist repair centre.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.
b) Batteries
• Ensure that you insert the batteries in the correct polarity.
• To prevent battery leakage, remove the batteries when you do not plan to use
the product for an extended period. Leaking or damaged batteries may cause
acid burns if they come into contact with your skin. Always use suitable protective
gloves when handling damaged batteries.
• Batteries must be kept out of the reach of children. Do not leave batteries lying
around, as there is a risk that children or pets may swallow them.
• All batteries must be replaced at the same time. Mixing old and new rechargeable
batteries can cause the batteries to leak and damage the product.
• Batteries must not be dismantled, short-circuited or thrown into flames. Never
attempt to charge non-rechargeable batteries, as this may cause an explosion!
c) Persons and product
• The magnets in the housing are very strong. Always maintain a sufficient distance
from magnetic objects, e.g. credit cards with magnetic strips and pacemakers.
• The casing of the angle gauge is made of conductive metal. Never measure on
live objects. This may cause a short circuit or a fatal electric shock!
• Always comply with accident prevention regulations when using the product in
industrial facilities.
• In schools, educational facilities, hobby and DIY workshops, the product must be
operated under the supervision of qualified personnel.
Product overview
5
4
3
2
1
LCD display icons
The undervoltage symbol (
) indicates that the batteries need to be replaced.
The
icon indicates a relative icon (to a zero point).
The
icon indicates that the displayed measurement is fixed.
The inclination symbol (
) indicates that there are two possible orientations for the
measured surface.
a) Inserting/changing the batteries
The angle gauge is powered by two 1.5 V AA batteries. Before using the product for the first
time, insert two 1.5 V batteries (not included).
• To insert the batteries, open the battery compartment (5) on the
back of the product (unscrew the screws with a suitable screwdriver
and remove the battery compartment cover).
• Insert the batteries in the correct polarity (+/-). Pay attention to
the polarity markings inside the battery compartment. Replace the
battery compartment cover to close the battery compartment (5).
• Screw all screws back into place.
• Change the batteries when the undervoltage icon (
Operation
The angle gauge is not designed to determine whether a large surface is level. This
should be done using a spirit level.
a) Switching on and off
• Press the ON/OFF/REF button (3) to switch on the angle gauge. All icons will briefly appear
on the display.
• Press and hold the ON/OFF/REF button (3) to switch off the angle gauge.
• The angle gauge switches off automatically after 3 minutes to save energy.
• Switch off the angle gauge when you have finished using it.
• When you are not using the angle gauge, place it in the storage pouch to protect it against
damage.
b) Measuring angles
• Turn on the angle gauge and place the bottom of the angle gauge on the surface that you
want to measure.
Correct
• Place the angle gauge on a surface (the bottom of the angle gauge contains a magnet that
attaches itself to ferromagnetic metal surfaces).
If the angle gauge is tilted too far from the level position, "Err" will be displayed and
you will not be able to take a measurement.
• The LCD display indicates the angle of inclination of the measurement surface in degrees (°).
The inclination icon (
) and the two arrow symbols ( or ) on the right-hand side of the
inclination icon indicate which side the angle gauge/surface must be tilted towards in order to
make it level. The right-hand side of the angle gauge is the reference edge.
1 HOLD button
2 MODE button
3 ON/OFF/REF button
4 LCD display
5 Battery compartment (not shown)
) appears on the LCD display.