DMX PARAMETER
Channel
CH1
CH2
OPERATION
POWER ON
Connect the machine to an appropriate mains outlet and switch the ON/OFF button to ON. The
RUN LED lights up in red. If a DMX controller is connected, the DMX light lights up in red.
DMX CONTROL
Connect a DMX512 controller via a DMX signal cable to the DMX IN connector. Push the pot meter
of channel 2 to the maximum. Wait about 7 seconds until the RUN indicator flashes in green.
Push the potmeter of channel 1 to the max and the machine will shoot sparks.
Lower both potmeters to the miniumum position. If you want to shoot sparks again, push the
potmeter of channel 2 to the top and wait until the RUN indicator flashes quickly in green. Then
push channel 1 to the max.
ERROR MESSAGES
Error code E1: Lack of granulate. Please fill granulate into the hopper.
Error code E3: Lack or leakage of gas. Replace the gas cartridges.
POWER OFF AND CLEANING
1. Turn off the machine.
2. Disconnect the power and the DMX signal cable.
3. Remove the gas cartridges and store them in a cool, dark, well ventilated place away from
sunlight.
4. Check if foreign objects have entered the machine and remove them.
SPECIFICATIONS
Power supply ........................................................................................... 100-240V~50/60Hz
Consumption ...................................................................................................................... 10W
Granule ................................................................................................Composite Ti (medium)
Powder consumption at max. output .................................................................................. 1g
Projection height ...................................................................................................................3m
Powder tank capacity .......................................................................................................... 70g
Gas cartridge ............................................................................. 2 x isobutane gas cartridges
................................................................................ with valve with a volume of 220g +/- 5g
...............................................................and a dimension of 68 (diam.) x 180m type cp 250
Gas consumption ................................................................................................... 8-10g/min.
Weight ................................................................................................................................. 16kg
Dimensions .............................................................................................. 400 x 350 x 285mm
IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local
authorities or your dealer about the way to proceed.
DMX address
0-9
10-255
0-9
10-255
www.afx-light.com
Function
Fire off
Fire on
Close gas loading
Start gas loading
5
EN