INSTALLATION
All Appliances – The maximum depth of overhead cabinets installed above the cooker
must NOT exceed 13ins (330mm). All combustible materials such as curtains and shelves
must be kept well clear of the appliance, and their installation should meet all relevant lo
and state regulations/standards in force.
IMPORTANT
• This appliance must be installed into an aperture, sealed off at either side in
order to prevent draughts from adjoining cupboards/vents. Ensure that air vents
and gas escape holes are kept clear, holes for cables and pipes mu st be sized to
minimize air leakage between compartments.
• Unde
r no circumstances should the ventilation hole exceed 3850mm
low level ventilation be located in the compartment, including vents in kickboards.
Low level vents in adjacent compartments are permitted.
•
Any cupboards beneath the appliance MUST be se
entering the living area.
Fixing
The
se appliances can be front or side fixed, holes are provided for either installation
me
thod. Fixing screw positions are located as follows.
Appl
iance
S~OH
70000Y
&
S~OH71000Y
2 fix hole
Gas Connection
A ¼ NPT female connection is provided for gas inlet, on the rear of the appliance. It is
recommended that the appliance be connected by copper tubing, a rubber or hose
connection must not be used. After connection the appliance must be tested for
soundness.
This appliance is suitable for use
It is important that the regulator should be s
bei
ng used. Excessive pressure must not be permitted.
If th
e flame on either the top burners or the grill show a tendency to lift, it is probabl
the
line pressure is too great. Should there be excessive yellow tips (resulting in
the
n it is probable that the line pressure is too low and, in either case, the burners shoul
not
be used until the line pressure has been checked.
The burners on this appliance hav
Front Fixed Appliance
2
front fix holes each side of
Oven opening
s each hotplate side trim
on –
Propane Gas Only
Max regulator inlet pressure
Regulator supply pressure
Manifold working pressure
e fixed aeration and no adjustment is necessary.
aled to prevent a gas escape
Side Fixed Appliance
2 side
2 fix holes each hotplate side trim
11 ins wc (
½ ins psi (34.5mbar)
12 ins wc (30.0mbar)
11 ins wc (27.5mbar)
et to the correct pressure for the type of gas
17
2
or other
fix holes each side of
Oven opening
27.4mbar)
e that
sooting)
cal
d