The Dirt Cup
The dirt picked up by the cleaner is deposited into the dirt cup.
When empty, the cup can be cleaned with a damp cloth or rinsed with water.
Be sure cup is dry before re-using.
When to Empty
Frequently check dirt level in the dirt cup.
It is recommended that you empty the cup when the dirt level reaches the "Full
Line" on back of cup.
If more dirt is allowed to accumulate, your cleaner may not operate effectively
and spillage may occur when cup is removed.
Peak performance of your cleaner can be maintained by turning the cleaner
off, unhooking bag spring, shaking the filter bag, and emptying the dirt cup
frequently before it becomes full. (Fig. 2.2)
How to Empty
Place handle in operating position and unhook spring from handle.
While holding bag closure clip, shake bag vigorously to release dirt accumulated in bag.
Re-hook spring and place handle in upright position. Allow a few seconds for
dirt to settle into cup.
While supporting bottom of cup, release the two latches by pulling them outward
as shown.
Remove cup and empty it
Reposition cup up into support at bottom of bag and snap latches into position.
The Belts
When to Replace
Disconnect cleaner from electrical outlet before checking or replacing belt.
To check belts, remove hood (see following section).
If either belt is stretched or cut; or if the agitator fails to rotate, replace the appropriate belt.
How to Replace
Disconnect cleaner form electrical outlet before checking or replacing belt.
Remove hood, by turning cleaner over and removing the 4 Phillips head screws indicated by arrows on
bottom of cleaner.
Return cleaner to original position.
Depress handle release lever to lower handle and then lift off hood.
6
2.1
2.2
FULL LINE