WARNING:
It is advisable to read the instructions carefully before you start installation.
the safety or correct operation of the device and hence of the entire system.
instructions.
The company reserves the right to make improvements to the products.
THIS BOOKLET IS TO BE USED ONLY BY THE INSTALLER
-
rent legal requirements.
ELECTRICAL CONNECTIONS
To ensure operator safety and to prevent damage to the components while connections are being
made, or when the radio card is being inserted, the control unit absolutely must not be powered on.
section that is suitable for the length (minimum 1.5 mm2).
For auxiliary power supplies, controls and safety contacts a minimum section of 0,5 mm2. When
the control cables are very long (more than 30 m), de-coupling is suggested using relays at the
control unit.
If a fuse trips, after removing the cause, replace it with another one of the same type. Install the
various safety devices, limit switches, photocells, sensitive rib, stop button.
If one or more of the safety devices are not installed, the corresponding terminals must be short
circuited with the controls common.
All contacts N.C. Assigned to the same input must be connected in series.
All contacts N.O. Assigned to the same input must be connected in parallel.
For the power supply of the control unit, there must be an external disconnecting switch (not includ-
ed), independent and properly sized.
ATTENZIONE
-
asi momento e senza obbligo di preavviso da parte di Key Automation S.p.A.
10