Troubleshooting
Malfunction
SensorLight without power
SensorLight will not switch ON
SensorLight will not switch OFF
SensorLight switches on when it
should not
SensorLight reach has changed
LED ON/flashes all the time
although manual override is not
selected
LED lamp flickers
Manufacturer's warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is in perfect condition and proper work-
ing order. The warranty period is 36 months, starting
on the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects shall
be excluded.
Cause
n Fuse faulty, not switched
on, break in wiring
n Short circuit
n Twilight control set to night-time
mode during daytime operation
n LED lamp faulty
n Mains switch OFF
n Fuse faulty
n Detection zone not properly
targeted
n Internal electrical fuse
has been activated
(LED ON all the rime)
n Continuous movement in the
detection zone
n Wind is moving trees and
bushes in the detection zone
n Cars in the street are being
detected
n Sudden temperature changes
due to weather (wind, rain,
snow) or air expelled from
fans, open windows
n Change in ambient
temperatures
n Internal fuse activated
n For technical reasons, at various
dimming levels
The warranty will only be honoured if the product is
sent to the appropriate Service Centre fully assembled
and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's
stamp).
Repair Service:
Please ask your nearest service centre how to pro-
ceed for repairing faults not covered by the warranty
or occurring after the warranty expires.
3
- 12 -
Remedy
n Fit new fuse, turn mains switch
on; check wiring with
voltage tester
n Check connections
n Re-adjust (control
n Change
n Switch on
n Fit new fuse, check connection
if necessary
n Re-adjust
n Switch OFF SensorLight or
check/change lamp and switch
back ON again after 5 sec
n Check detection zone and
re-adjust if necessary
n Change detection zone
n Change detection zone
n Change detection zone,
change site of installation
n Use shrouds to adjust detection
zone accurately
n Switch OFF SensorLight or
check/change lamp and switch
back ON again after 5 sec
n Alter dimming level
Y E A R