Télécharger Imprimer la page

STEINEL L 260 S Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in addi-
tion to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Switch 1 x OFF and ON.
Light stays on for the period selected.
2) Switch light OFF (when light is ON):
Switch 1 x OFF and ON.
The light goes out or switches over to sensor mode.
Soft light start
The sensor light features a soft light start function.
This means that when turned on, the light is not
switched directly to maximum output but gradually
Reach setting/adjustment
At an assumed installation height of 2 m, the sensor
has a maximum reach of 12 m. The detection zone
can be optimised to suit needs. The shrouds provided
are used for blanking off any number of lens segments
or to shorten reach as required. This prevents the
light from being activated unintentionally, e.g. by
cars, passers-by etc. and allows you to target danger
spots. The shrouds can be divided or cut with a pair
of scissors along the vertical and horizontal grooves.
Operation/Maintenance
The sensor light is suitable for switching light on
automatically. Weather conditions may affect the way
the sensor light works. Strong gusts of wind, snow,
rain or hail may cause the light to come on when
it is not wanted because the sensor is unable to
distinguish sudden changes of temperature from
sources of heat. The detector lens may be cleaned
with a damp cloth if it gets dirty (do not use cleaning
agents).
Disposal
Electrical and electronic equipment, accessories and
packaging must be recycled in an environmentally
compatible manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
Manual override
1) Switch ON manual override:
Switch ON and OFF twice. The light will stay ON for
4 hours (red LED lights up behind the lens). Then it
returns automatically to sensor mode (red LED off).
2) Deactivate manual override:
Switch ON and OFF once. Light goes out or changes
over to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
builds up brightness to 100 % within the space of a
second. Brightness is also gradually reduced when
the light is switched OFF.
After removing the decorative ring, the shrouds can
be clipped on at the top of the sensor lens. The
decorative ring must now be pushed back on to
hold the shrouds firmly in place.
Precision targeting can be achieved by turning the
sensor housing through ± 80°
Light source can be changed by consumer.
EU countries only:
Under the current European Directive on Waste
Electrical and Electronic Equipment and its imple-
mentation in national law, electrical and electronic
equipment no longer suitable for use must be collect-
ed separately and recycled in an environmentally
compatible manner.