Technical specifications
Dimensions (H x W x D):
Power supply:
Power consumption (Pon)*:
Luminous flux*:
Efficiency*:
Standby light:
Colour temperature*:
Colour rendering index*:
Average rated life expectancy*:
Colour consistency SDCM*:
Luminous intensity distribution*:
Angle of coverage:
Detection reach:
Twilight setting:
Time setting:
Manual override:
IP rating:
Protection class:
Ambient temperature:
Contains an energy efficiency class F light source
* For LED lamp provided with the light
Functions
,
The SensorLight can be put into service after mount-
ing the sensor unit and connecting the light to the
mains power supply.
Switch-off delay
(time setting)
(factory setting: 5 sec.)
Twilight setting
(response threshold)
(factory setting:
daylight operation 2000 lux)
426 x Ø 102 x 177 mm
220-240 V/50 Hz
9.2 W / E27
927 lm
101 lm/W
0.9 W
3000 K (warm white)
Ra = 82
L70B50 at 25° C: > 20,000 hours.
starting value: 3
150°
180°
150°
120°
120°
90°
90°
20
40
60
60°
60°
80
100
30°
30°
C
0
/
C
1
8
0
C
9
0
/
C
2
7
0
cd / 1000 lm
240° with 180° angle of aperture
Max. 12 m
2-2000 lux
5 sec. - 15 min.
Selectable (4 hrs.) / provided switch is connected in mains power supply lead
IP44
I
- 20°C to + 40°C
Light ON duration can be infinitely varied from
5 sec. to 15 min.
Control dial set to 1 = shortest time (5 sec.)
Control dial set to 6 = longest time (15 min.)
5 sec. - 15 min
It is recommended to select the shortest time
(setting 1) for adjusting the detection zone.
The sensor's response threshold can be infinitely
varied from 2–2000 lux.
Control dial set to 1 = daylight operation approx.
2000 lux.
2-2000 lux
Control dial set to 6 = twilight operation approx.
2 lux.
To adjust the detection zone in daylight, the control
dial must be set to number 1 (daylight operation).