6.2- Breakdown
- Never attempt to dismantle the pump.
- If necessary, have it checked and repaired by an authorized centre (consult your dealer).
6.3- Trouble shooting
Incidents
Pump does not start
No flow
Pump does not switch
off
Insufficient flow
Pump switches of
after short operating
period
6.4- Storage
- Clean the pump.
- Pump must be stored in a dry, ventilated location. Always lock up product and keep out of reach of
children.
6.5- Disposal
- Do not dispose the product with household garbage. Do not throw into the environment.
- Dispose of the product in a collection centre for waste of electrical and electronic equipment, or a waste
drop-off centre; or seek advice from your local municipality.
- Disposal of the product, accessories and packaging should be carried out according to local regulations
governing environment protection.
Causes
-Power supply not connected
-Floater does not switch
-Inlet sieve is clogged
-Pressure hose in bent
-Floater cannot sink down
-Inlet sieve is clogged
-Reduced pumping capacity by dirty and
abrasive water
- Dirty water: thermal cut-out stops pump
- Water too hot: thermal cut-out stops
pump
Remedies
-Check power supply
-Raise position of floating switch
-Clean inlet sieve water jet
-Reset hose
- Place pump vertically underwater
-Clean inlet sieve
-Clean pump and replace worn-out parts
-Remove mains plug. Clean pump and shaft
-Make sure that a water temperature of
max.35℃ is not exceed
Page 18 / 26