90° Vertical Beam Accuracy
You will need at least 1,5 m
1.
Place the laser unit (without its mounting
bracket) on a level floor, and turn on all
beams (mode 4).
2.
Measure exactly 0,91 m (3 ft) out from the
center of the laser unit along the vertical
beam of the laser cross. To easily refer-
ence the center of the laser unit start the
first measurement against the outer base
of the laser unit, measure out 0,91 m (3 ft),
and then subtract 4,3 cm (1,69 in). Mark
this point P
1
3.
Measure exactly 1,22 m (4 ft) out from the
center of the instrument along the at 90°
vertical reference beam, and mark this
point P
.
2
4.
Measure from point A to point B; this
distance D
should equal 1,522 m ± 0.75 mm
1
(5 ft ± 1/32 in). If not, the unit must be
returned to your Stanley Distributor.
5.
Repeat steps 1 through 4, as needed, to
recheck the measurements.
16
(16 ft
) of floor space and possibly an assistant for this check.
2
2
.
P
1
0,91 m (3 ft)
P
1
1,22 m (4 ft)
P
P
1
D
1
P
2
2
77-021