Function values
CV61
Back-EMF: Adjustment frequency
Specifies how often per second the motor voltage is
adjusted -accordingly, the loco will react to curves and
grades immediately or with a short delay
0 = immediate adjustment, 255 = maximum delay
CV62
Back-EMF: Max. Adjustment
Limits the total adjustment in motor voltage. If there is
a very large load on the motor, the adjustment will not
exceed this value - for more realistic operations, so that
locos will slow a bit on grades.
0 = no adjustment, 255 = maximum adjustment
CV67
Speed steps programmed by user (see CV29):
to
28 speed steps are programmed in CV67 to CV94.
CV94
With LGB MTS, every second value is skipped
(14 speed steps). Factory pre-set speed steps: 7, 9, 11,
13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76, 84, 92,
102, 112, 124, 136, 152, 168, 188, 208, 230, 255
Pre-set values for user-programmable speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112,
120, 128, 136, 144, 152, 160, 168, 176, 184, 192, 208,
224, 240, 255
Hint: The speed steps are factory pre-set and pro-
gramming is not necessary. We recommend the
55045 MTS PC Decoder Programming Module for
programming.
Available
Factory
pre-set
(0-255)
[5]
(0-255)
[255]
(0-255)