EGC-BS-KF, EGC-HD-BS
• Attach the EGC as follows:
• Please select the corresponding accessories from our catalogue (
Foot mounting
HPE (EGC-...-BS-KF only)
Attach foot mounting to the
threads and centring holes 7
(
Fig. 1) in the bearing caps
Tab. 1
• Tighten all of the mounting screws to the same tightening torque according to the following table.
Size
Screw
HPE
MUE
NST
Tightening
HPE
torque
MUE
NST
Tab. 2
Fitting in a vertical or sloping position:
Warning
Injury to people and damage to property.
If there is a power failure or if the spindle nut
breaks, the work mass will fall.
• Make sure that you only use motors with an
integrated spring-loaded holding brake.
• Check whether additional external safety
measures to protect against spindle nut frac-
ture are necessary (e.g. toothed latches, mov-
ing bolts or emergency buffers).
26
Profile mounting
MUE
Profile mounting in the slot of
the mounting surface 8
70
80
M5
M5
M5
M5
M5
M5
[Nm]
5.9
5.9
[Nm]
5
5
[Nm]
5.9
5.9
www.festo.com/catalogue).
Slot nut mounting
NST
Slot nut mounting in the groove
aJ. When tilted the slot nuts
slide into the groove at each
point on the profile
120
125
160
M8
–
–
M8
M5
M5
M8
M5
M5
24
–
–
20
5
5
24
5.9
5.9
Fig. 5
Festo – EGC-BS-KF, EGC-HD-BS – 1204c English
185
220
M10
–
M8
M8
M8
M8
47
–
20
20
24
24