Technical Data
The following table lists input values for the appliance.
Burner
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
Orifice Sizes(see above)
Gases / Pressures
Countries
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table
above. For replacement, use only the regulator specified by the manufacturer.
www.napoleon.com
Do not route hose underneath drip pan.
Ensure all connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on
any hose connection.
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak
causing a fire.
Orifice Size
I
II
#69 (0.74 mm)
#73 (0.61 mm)
I
3B/P(30)
I
Butane and Propane
at 30mbar
BE, BG, CY, DK, EE,
FI, FR, GB, HR, HU,
IS, IT, LT, LU, MT, NL,
NO, RO, SE, SI, SK,
TR
(Gross) Heat Input (Total)
I
II
4.1kW
4.1kW
I
3+(28-30/37)
I
Butane 28-30mbar
Propane 37mbar
BE, CH, CY, CZ, ES,
FR, GB, GR, IE, IT, LT,
LU, LV, PT, SK, SI
Gas Usage (Total)
I
II
301 g/hr 301 g/hr
I
3B/P(50)
II
Butane and Propane
at 50mbar
AT, CH, DE, SK
N415-0309CE-GB-DE DEC 29.20