Correct use
The CRX101 - CRX1026 tubular drives are designed for the exclusive purpose of operating shutters and sun-blind systems.
They serve to open and close these systems and replace the person that is usually operating the installation.
Therefore, tubular drives may only be installed in faultless shutter- or sun-blind systems. Rough-running systems have to be repaired.
Replace defective parts. This guarantees safe operation and avoids damage during opening or closing.
Any other form of usage is deemed to be incorrect. Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to
property or consequential injury or damage occurring as a result of the use of the control units and / or drives for purposes other than those
mentioned above or due to changes made to the equipment affecting the safety of the given system.
The details stipulated in the Operating Instructions in respect of the operation and repair of the system require strict observance. Neither the
manufacturer nor the supplier assumes any liability for personal injury, damage to property or consequential injury or damage occurring
as a result of non-compliant actions.
In compliance with standard EN 60 335-2-97:2000, the cable connecting the drives to the mains cable must be laid internally.
According to DIN 18073 shuter box lid must always be easily accessible and removable.
Performance features
Model
Diameter*
Torque
(mm)
(Nm)
CRX101
35
10
CRX151
45
15
CRX251
45
25
CRX401
45
40
CRX501
45
50
CRX800
59
80
CRX1000
59
100
CRX0628
35
6
CRX1026
45
10
*Smallest possible tube diameter for operators with body diameter of 35mm = 39mm
Smallest possible tube diameter for operators with body diameter of 45mm = 50mm
Smallest possible tube diameter for operators with body diameter of 59mm = 70mm
INSTALLATION
Rough- in or install conduit pipe to the connector box for the electrical connecting line according to local building and electrical codes.
THE DRIVE IS PREMOUNTED. THE DESCRIPTION IS FOR CHECKING PURPOSES!
A
Carton Contents
1.
Motor (1)
2.
• Adjuster pin (2)
• Drive adapter safety catch (3)
• Square pin (4)
• Shaft adapter (5)
• Wall bracket (6)
3.
Manual
Fully unroll the shutter (a). Remove the shutter material from
B
the tube (b). Remove the manual control (c).
b
Speed
Operating
Frequency
Voltage
(rpm)
(V)
(Hz)
17
230
50
15
230
50
15
230
50
15
230
50
12
230
50
15
230
50
12
230
50
28
230
50
26
230
50
CRX800, CRX1000 only
c
a
Current
Motor
input
rating
(A)
(W)
0,53
121
0,60
133
0,83
191
0,86
198
0,89
205
1,43
330
1,54
345
0,53
121
0,64
145
A
A
CRX101 - CRX501
3
not included in CRX800, CRX1000
C
Remove the tube.
Operating
Limit switch
time
range
(min)
(revolutions)
4
39 +/- 1
4
23 +/- 1
4
23 +/- 1
23 +/- 1
4
23 +/- 1
4
21,5 +/- 1
4
21,5 +/- 1
4
4
39 +/- 1
4
23 +/- 1
5
4
1
5
2
6