Adjustment
Make this adjustment only if the cartridge you
are using makes it necessary.
Preparation
Put a record on the turntable.
1
Release the arm lock.
Arm lock
(Released)
2
Adjust the height with the arm-
height adjuster.
Adjust the arm height until the tone arm
becomes parallel to the record.
Use the chart below as reference to find the
appropriate position mark for the height of
your cartridge.
(For supplied head shell)
Cartridge height
(H) in millimeters
Height of the accessory cartridge H = 18 (mm)
(Height control position : 4)
16
(16)
English
(continued)
Tone arm height
(Locked)
Height control
position
14
0
15
1
16
2
17
3
18
4
19
5
20
6
Hold the arm-height adjuster and slide it up
or down to align the position mark with the
index line. 0 to 6 mm are marked on the arm
height adjuster.
When checking the index line of the Arm-
height adjuster, check with your eyes on the
same level.
When you don't know the cartridge
height (H) or when you don't use
the accessory head shell
Remove the stylus cover, taking care not to
damage the stylus, then release the arm clamp.
Lower the cue lever, rest the stylus on the
record and adjust the height control until the
tone arm and record are parallel.
If the cartridge height (H) is too small to
make them parallel to each other, add a
"cartridge spacer" (not supplied).
Parallel to a record
Arm-height
adjuster
Index line