Display
Type of error You have the following
Chlorine-related errors
unclear
b04
analyses
unsuitable
b05
production
low
b06
production
problem
impossible to
b40
get a reading.
impossible to
b41
get a reading.
impossible to
b42
get a reading.
chlorine
b60
reagent
chlorine
b61
reagent
b99
salt card
pH-related errors
inconsistent
E04
analyses
unsuitable
E05
production
lower produc-
E06
tion problem.
lower produc-
E07
tion problem.
pH reagent
E60
pH reagent
F61
problem:
there is an air bubble
in the analysis circuit
there has been an external
addition of chlorine
the stabiliser content
is too high
there is a lack of salt/The
electrode has come to the
end of its life/If you have
a chlorine pump, the liquid
chlorine may have run out
the water contains too many
impurities
too much air is getting into
the circuit
either the sampling pump
or the analysis circuit is
defective
there is no more reagent /
The chlorine reagent has not
been added properly
the chlorine reagent tank will
soon be empty
check the amperage and
voltage in the diagnostics
menu
there is an air bubble in the
analysis circuit
there has been an external
addition of pH
check the level of the pH+
corrector tank: it is empty or
almost empty
check the level of the pH-
corrector tank: it is empty or
almost empty
there is no more reagent /
The pH reagent has not been
added properly
the pH reagent will soon be
empty
Here is how to resolve it.
eliminate any air getting in
check the constants and the
production parts (electrolyser, cell,
chlorine pump, level in the chlorine
tank, etc.) and adjust the produc-
tion settings
check the constants and the
production parts (electrolyser, cell,
chlorine pump, level in the chlorine
tank, etc.) and adjust the produc-
tion settings
check the quality of the water
analysed
eliminate any air getting in
check the analysis circuit
repeat the addition of the chlorine
reagent, or change it
get ready to change it / You have
not reinitialised your reagent gauge
call a technician about this
eliminate any air getting in
check the pH pumps and the level
of the pH corrector tanks
prepare to change it
prepare to change it
repeat the addition of the pH
reagent or change it
get ready to change it / You have
not reinitialised your reagent gauge
Intervention by
a technician
yes / no
no
no
no
yes
yes
no
no
yes
yes / no
no
no
no
no
no