7. MAINTENANCE
How to change the membrane
If after reviewing the trouble-shooting guide you find that you need to replace the membrane,
please follow the steps below: (We strongly recommend seeking the assistance of an expert)
• Unscrew the tank valve cover
zero.
• Unscrew the flexible hose from the tank flange.
• Use a wrench to remove the 6 bolts from flange.
• Remove the flange.
• Remove the defective membrane, and replace it with a new one.
• Remount the flange and the flexible hose in reverse order.
• Inflate the tank to 1.8 Bar via the boiler valve.
• Screw the tank valve cover back on.
Storage
• Place the 2 connectors caps
pump.
• If there is a risk of frost, the pump must be drained complete.
• After long periods of stoppage make sure the rotor turns correctly by briefly switching the
pump on and off.
• If the pump is not going to be used for a long time or has to be removed for the winter
months, rinse it out with water, empty it completely and allow it to dry.