EBI 25-TX
Unit
Tempera-
ture
Sensor
PT 1000
Resolution
0.1 °C
Measurement range -200 ... +199.9 °C
Accuracy
±2 °C (-200 ... -100 °C)
±0.5 °C (-100 ... -20 °C)
±0.4 °C (-20 ... +60 °C)
±0.5 °C (+60 ... +199.9 °C)
Valid
probes!
Probe connection
Binder series 620
Protection class
IP67
Dimensions
(L x W x H)
106 x 48 x 27 mm
Battery life time and storage capacity
The battery life time is reduced when operating at a
measurement interval under 15 minutes and a tempera-
ture below +25 °C. In extreme cases (1 minute interval,
temperatures below 0 °C) the battery will last only one
month.
The logger sends its data at its measurement interval.
Should it not be able to reach the base station IF 400, it
will store its measurement data internally. At 15 minutes
measurement rate this will last for three days. At 5
minutes it will last for one day. At one minute it will last
for unter 5 hours.
08/2021 ba80003def08_EBI25
only
for
calibrated
Français
EBI 25-TX
Grandeur d. mesure Température
Sensor
Résolution
Plage de mesure
Exactitude
Connexion de sonde Binder Serie 620
Classe protection
Dimensions
(L x l x H)
Durée de vie de la batterie et capacité de
stockage
La durée de vie de la batterie est réduite lorsqu'elle fonc-
tionne à intervalle de mesure inférieur à 15 minutes et
une température en dessous de +25 ° C. Dans les cas
extrêmes (intervalle de 1 minute, températures inféri-
eures à 0 ° C) la batterie ne durera qu'un seul mois.
L'enregistreur envoie ses données à son intervalle de
mesure. S'il ne parvient pas à atteindre la station de
base IF 400, il stockera ses données de mesure en in-
terne. À 15 minutes taux de mesure cela durera trois
jours. À 5 minutes il durera un jour. À une minute, cela
durera un 5 heures.
33
PT 1000
0,1 °C
-200 ... +199,9 °C
±2 °C (-200 ... -100 °C)
±0,5 °C (-100 ... -20 °C)
±0,4 °C (-20 ... +60 °C)
±0,5 °C (+60 ... +199,9 °C)
Valide seulement pour les
sondes calibrées!
IP67