Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10.1 - WIRING DIAGRAM

Terminals Description
PE,L, N
230Vac power line Take extra care
to fasten the 3 cables in each of
the 3 terminals.
4
Barrier opening N.O. contact
5
Barrier closing N.O. contact
6
Open common contact
7
Close common contact
8
Stop N.C. contact
9
Stop common contact
10
Barrier end stroke N.O. contact
(1) The station is disabled if contact 12-13 is closed. It is used, for instance, to comply with a give way sig-
nal.
(2) Open collector 50mA 24V output. It is activated when the barrier is opened following an accepted
transit request (valid or correctly collected ticket, valid season ticket). This output is used for the Sacs
space counting system (CAPACITY KIT) .
(3) Open collector 50mA 24V output. It is activated when the detection loop is triggered.
30 - Aura20 U
Terminals Description
11
Barrier end stroke common contact
(2)
Transit in progress contact
15
Transit request contact
(3)
16
(3)
Transit request contact
17
18
Detection loop
19
Detection loop
20
Safety loop
21
Safety loop

Publicité

Table des Matières
loading

Table des Matières