12.1 - WIRING DIAGRAM
Termi-
Description
nals
L, N
230Vac power line Take extra
care to fasten the 2 cables in
each of the 2 terminals.
1
Traffic lights supply
2
Red traffic light
3
Green traffic light
4
Barrier opening N.O. contact
5
Barrier closing N.O. contact
6
Open common contact
7
Close common contact
8
Stop N.C. contact
9
Stop common contact
10
Barrier end stroke N.O. contact
(1) The station is disabled if contact 12-13 is closed. It is used, for instance, to comply with a give way sig-
nal.
(2) Open collector 50mA 24V output. It is activated when the barrier is opened following an accepted
transit request (valid or correctly collected ticket, valid season ticket).
(3) Open collector 50mA 24V output. It is activated when the detection loop is triggered.
32 - Espas30 I
1 2 3
L
N
Termi-
Description
nals
11
Barrier end stroke common
contact
Station disabling contact
(1)
12
Station disabling contact
(1)
13
(2)
Transit in progress contact
14
(2)
Transit in progress contact
15
(3)
Transit request contact
16
(3)
Transit request contact
17
18
Detection loop
19
Detection loop
20
Safety loop
21
Safety loop
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4