4
Temperature tables
Measuring system Promag 53 (compact version)
at T
= 40 °C
a
Promag H
DN 2...100
Promag P
DN 25...200
Promag P
DN 15...600
Promag W
DN 65...2000
at T
= 45 °C
a
Promag H
DN 2...100
Promag P
DN 25...200
Promag P
DN 15...600
Promag W
DN 65...2000
at T
= 50 °C
a
Promag H
DN 2...100
Promag P
DN 25...200
Promag P
DN 15...600
Promag W
DN 65...2000
Sensor Promag (remote version)
at T
= 50 °C
a
Promag H
DN 2...100
Promag P
DN 25...200
Promag P
DN 15...600
Promag W
DN 65...2000
* Time limit of max. 10 min.
at T
= 60 °C
a
Promag H
DN 2...100
Promag P
DN 25...200
Promag P
DN 15...600
Promag W
DN 65...2000
Transmitter Promag 53 (remote version)
The Promag 53***-******H***** transmitter has a T6 temperature class rating at a
ambient temperature up to T
The maximum ambient temperature range is –20...+60 °C (depending on the area of
application).
Note:
At the specified medium temperatures, the equipment is not subjected to temperatures
impermissible for the temperature class in question.
PROline Promag 53 FOUNDATION Fieldbus
T6
80
(PFA lining)
80
(PTFE lining)
80
(hard-rubber lining)
80
T6
80
(PFA lining)
80
(PTFE lining)
80
(hard-rubber lining)
80
T6
80
(PFA lining)
80
(PTFE lining)
80
(hard-rubber lining)
80
T6
80
(PFA lining)
80
(PTFE lining)
80
(hard-rubber lining)
80
T6
80
(PFA lining)
80
(PTFE lining)
80
(hard-rubber lining)
80
= 60 °C.
a
Max. medium temperature [°C] in
T5
T4
T3
T2
95
130
150
150
95
130
150
150
95
130
130
130
80
80
80
80
Max. medium temperature [°C] in
T5
T4
T3
T2
95
130
130
130
95
130
130
130
95
130
130
130
80
80
80
80
Max. medium temperature [°C] in
T5
T4
T3
T2
95
95
95
95
95
95
95
95
95
95
95
95
80
80
80
80
Max. medium temperature [°C] in
T5
T4
T3
T2
95
130
180
180
95
130
180*
180*
95
130
130
130
80
80
80
80
Max. medium temperature [°C] in
T5
T4
T3
T2
95
130
150
150
95
130
130
130
95
130
130
130
80
80
80
80
Endress+Hauser
T1
150
150
130
80
T1
130
130
130
80
T1
95
95
95
80
T1
180
180*
130
80
T1
150
130
130
80