9. Technical data
Maximum power:
Minimum operating
temperature:
Maximum operating
temperature:
Power Supply:
Safety Appliances:
Fuse (not changeable)
rating:
230 V = T 500 mA / 250 V
100 - 120 V = T 250 mA / 250 V
Dimensions
(W x H x D):
Weight, approx.:
12. Troubleshooting
Error
No display / no op-
eration, although the
unit is switched on
the main switch (A).
The unit is operat-
ing but there is no
increase in tempera-
ture.
Temperature has
been changed but is
not saved.
EN
23 W (+/- 10 %)
60 °C [140 °F]
110 °C [230 °F]
230 V / 50 - 60 Hz
100 - 120 V / 50 - 60 Hz
90 x 65 x 98 mm
[3.54 x 2.56 x 3.86 inch]
400 g [14.1 oz]
Possible cause
• Power supply interrupted.
• Faulty overheat fuse.
• Faulty unit fuse.
• Faulty thermal sensor.
• Faulty heater.
• Mains supply interrupted be-
fore saving values (5 seconds
after changing values).
10. Scope of Delivery
1 hotty LED Wax dipping unit
1 Operating Instructions
11. Accessories
GEO-Dip Dipping Wax (elastic):
No. 482-3000
No. 482-3200
No. 482-3300
Rewax Dipping Wax (hard, non-elastic):
No. 651-0000
• Check the power supply
• Have fuse replaced by
• Have fuse replaced by
• Have probe replaced by
• Have heater repaired by
• Change again tempera-
- 4 -
GEO-Dip yellow, 200 g
GEO-Dip orange, 200 g
GEO-Dip green, 200 g
Rewax yellow, 210 g
Corrective action
and power cords.
Service Department.
Service Department.
Service Department.
Service Department.
ture and turn off unit only