3.6
DEACTIVATION AND SHUTDOWN FOR PROLONGED PERIODS
To deactivate the heat pump proceed as follows:
This way the circulation pump anti-locking function remains active.
If the heat pump is not used for a prolonged period of time, the following operations should be carried out:
Cutting power also to the internal unit deactivates the circulation pump anti-locking function and the pump may need to be released
To restart the air-water heat pump after a long period of heat pump inactivity, contact a Service Technician.
3.7
CLEANING
The only cleaning required of the system supervisor is to clean the outer panels of the air-water heat pump using a cloth dampened
with soap and water.
Dry the surfaces carefully after cleaning.
3.8
SCHEDULED MAINTENANCE
Scheduled maintenance is essential for keeping the heat pump in perfect working condition, safe and reliable over time. This can
be done, every six months for some interventions and annually for others, by the Service Technician, who is technically authorised
and trained, and will use original spare parts.
The maintenance plan that the OLIMPIA SPLENDID service technician or the maintenance engineer must adhere to, on an
annual basis, includes the following operations and checks:
3.9
ALARMS
3.9.1
Alarms on internal unit display
Table 6 shows the alarms or overrides that can appear on the control panel display.
When an alarm activates, the mnemonic symbol appears on the display, LED 5
contact between terminals 16 and 17 is closed.
Override/Alarm Code
Override #1
Override #2
Override #3
Override #4
Override #5
Override #6
Allarme #1
Allarme #2
Allarme #3
Mnemonic on display
Or1
Entering water temperature below 10°C
Or2
Exchanger frost-protection
Or3
Heat source activation request active
Or4
Or5
External unit capacity limitation
Or6
Defrost cycle in progress
A1
Outlet water sensor faulty
A2
Inlet water sensor faulty
A3
Domestic water tank sensor faulty
switches on simultaneously and the alarm
Override/Alarm Description
3