Follow the instructions given in this manual closely in order to achieve a successful installation and optimum performance.
Failure to apply the indicated regulations, which may cause the appliance to malfunction, relieves OLIMPIA SPLENDID of any
form of warranty and of any damage caused to persons, animals or property.
The electrical system must comply with current regulations, as stated in the Technical Features chapter, and be correctly earthed.
The appliance must be installed in an accessible position to enable maintenance to be carried out.
2.1
INTERNAL UNIT INSTALLATION
Prepare:
can be carried out
The internal unit must always be wall-mounted at head height, inside the residence.
2.1.2
Access to internal components
located on the right-hand side of the panel. The electric panel can be detached and attached using the grooves on the right-
or maintained more easily.
A Cables inlet
B Internal unit power terminal board
C Utility connections terminal board
D Cable grips
E Electrical heater elements thermomagnetic circuit breaker
F Safety contactor for electrical heater elements
G Elements relay
H
I
Control electronic board
L Fuse 250V 5A T
2.2
EXTERNAL UNIT INSTALLATION
the external unit could cause damage to persons or property, if it should detach from the base.
It is very important that the installation place be chosen with extreme care in order to ensure adequate protection of the device
against impact or possible consequential damage.
Choose a place that is adequately ventilated and in which the outdoor temperature in summer does not exceed 46°C.
Prepare a layer of gravel underneath the appliance for drainage of the defrost water.
Leave space underneath the unit to prevent the defrost water from freezing. In normal situations, ensure the base is at least 5
When installed in a location with high snow fall, mount the support of the appliance at a height that is above the maximum level
of snow.
Install the unit so that wind is not blowing across it.