er upon purchase of a new, equivalent product. Local regula-
Warnings: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right
to apply modifications to products at any time when deemed necessary, maintaining the same intended use and functionality.
Power supply:
Absorption:
Displays:
"RES" input:
Outputs 1 – 12:
Signal outputs:
Output capacity:
Radio receivers:
Radio encoding:
Number of devices:
Radio range:
Temperatures:
Protection rating:
Weight:
Dimensions:
(*) The range is strongly influenced by other devices operating on the same frequency with continuous transmissions that interfere
with the receiver.
TECHNICAL SPECIFICATIONS
12 V
± 2 V
60 mA standard
12 alarm leds + 4 fault leds
alarm memory control and deletion (with programmable polarity)
programmable NC / NO relay contacts
Tamper - Battery - Supervision – R.F Noise: programmable NC / NO relay contacts
Maximum 0.1 A and 35 V (standard 12 V
2; at 433MHz and 868 MHz; sensitivity - 105 dBm
Nice HS
up to a total of 32
100 m in open field free of disturbance or approx. 20m inside buildings (*)
operation: -10 ÷ 40 °C; storage -20 ÷ 70°C
IP 32
400 g
161 x 110 x 30 mm
tions can envision heavy sanctions in case of abusive dis-
posal of this product.
)
English - 7