3.2 - Output function selection
During memorisation of the devices, activation of the alarm
can be programmed in the case of an alarm (Table 2); to do
this, proceed as follows:
01. Select the required output by pressing S2 repeatedly
(SEL.CAN); the relative led of the ALL output illuminates;
02. Press the key S3 repeatedly (PROG.OUT) to select the
required function (see number of flashes in Table 2);
03. Memorise one or more devices for each output, perform-
ing the action specified in Table 1.
The efficiency of an output (opening and closing) can be
checked by simply passing from one function to another as
described in point 02.
3.3 - Deleting all devices memorised on all outputs
of HSRE12
To delete all memorised devices, proceed as follows:
01. Press and hold key S1, then power up;
02. Wait for 10 seconds, keeping key S1 pressed; a
BEEP confirms deletion of the devices;
03. Release S1; Led 1 starts flashing to indicate the wait
time for memorisation of the devices.
3.4 - Deleting all devices memorised on one output
of HSRE12
All devices memorised on a single output can be deleted as
follows:
01. Press S1 (PROG) to activate programming mode; a
BEEP indicates the start of programming;
02. Press key S2 (SEL.CAN) repeatedly to select the re -
quired output;
4 - English
03. Press and hold key S1; wait 10 seconds and then a
BEEP confirms deletion of the devices on the selected
output;
04. To delete other devices on other outputs, repeat points
02 and 03.
3.5 - Dip Switch configuration
There are 6 dip switches on the HSRE12 receiver, which
enable configuration of a number of operating parameters;
see Table 3.