Control - Menus
Main menu
Sub-menus
Status information for the relevant menu can be found
on the display to the right of the sub-menus.
temperature
Setting the temperature for the climate
system. The status information shows the set value for
the climate system.
temporary lux
Activation of temporary increase in the
hot water temperature. Status information displays
"off" or what length of time of the temporary temper-
ature increase remains.
ventilation
Setting the fan speed. The status informa-
tion shows the selected setting. This menu is only dis-
played for the exhaust air heat pumps and ground
source heat pumps with the exhaust air module access-
ory.
operating mode
Activation of manual or automatic
operating mode. The status information shows the se-
lected operating mode.
service settings
Setting which climate system is to be
controlled by the room unit. Hold the back button in
for 7 seconds to access the Service menu.
Menu 1 - temperature
If the house has several climate systems, this is indicated
on the display by a thermometer for each system.
Setting the temperature (without room sensors
activated):
Setting range: -10 to +10
The display shows the set values for heating (curve
offset). To increase or reduce the indoor temperature,
increase or reduce the value on the display.
Use the arrow buttons to set a new value. Confirm the
new setting by pressing the OK button.
The number of steps the value has to be changed to
achieve a degree change of the indoor temperature
depends on the heating unit. One step for under floor
heating whilst radiators may require three.
Setting the desired value. The new value is shown on
the right-hand side of the symbol in the display.
Set the temperature (with room sensors installed
and activated):
Setting range: 5 – 30 °C
The value in the display appears as a temperature in
°C if the heating system is controlled by a room sensor.
To change the room temperature, use the arrow but-
tons to set the desired temperature in the display.
Confirm the new setting by pressing the OK button.
The new temperature is shown on the right-hand side
of the symbol in the display.
Caution
An increase in the room temperature can be
slowed by the thermostats for the radiators or
under floor heating. Therefore, open the
thermostat valves fully, except in those rooms
where a cooler temperature is required, e.g.
bedrooms.
TIP
Wait 24 hours before making a new setting,
so that the room temperature has time to
stabilise.
GB
19