Screen 45
CHECk
WATER FLOW METER
11.7 Possible water leak signalling screen
Screen 46
WARNING POSSIBLE
LOSS OF WATER
11.8 Volumetric counter alarm
On models TOP 85, all equipped with six-LED bar, if there is no detection of impulses of the volumetric coun-
ter for 5 seconds, the LED's that are already on will start flashing to indicate the anomaly. If the anomaly is
detected before any of the LED's on the bar come on, only the LED of the short coffee key for the concerned
group will flash.
If no impulses of the volumetric counter are detected for 45 consecutive seconds, the amount of coffee being
served is automatically interrupted. GX COUNTER ALARM
Note:
Make sure that serving into the cup has taken place correctly. If serving has not occurred correctly, see the
chapter "PROBLEMS AND SOLUTIONS".
11.9 Autolevel alarm
If the water level in the boiler is below normal and the pump is not able to restore that level after 200 seconds,
the electronic control unit of the machine will stop automatic filling and signal the problem via simultaneous
flashing of the double short coffee button of all groups plus the large tea key and the first of the three LED's
of the electronic level control.
Note:
The following appears on the display: LOW BOILER WATER LEVEL. If the boiler is not properly filled with
water, see the chapter on problems and solutions .
11.10 Maximum water level in boiler alarm
If the level of water in the boiler is over the safe level, the electronic control unit will stop automatic filling and
signal the problem through simultaneous flashing of the serving buttons plus the three LED's of the electronic
level control. LOW BOILER WATER LEVEL.
Note:
If the maximum boiler level alarm trips, see the chapter on problems and solutions
11.11 Alarm for temperature sensor
If the level of water in the boiler is above the safety level, the electronic control unit will stop automatic loading and
signal the fault by making the brewing buttons flash at the same time together with the three electronic level leds
and the following appears on the display: BOILER WATER LEVEL TOO hIGh.
If the temperature probe is short circuiting, the following appears on the display: BOILER TEMPERATURE
Water counter check signalling screen.
This appears if the counter does not detect the impulse count while
brewing or the load for self levelling at the end of brewing or auto
levelling.
This screen will not be displayed if the water counter was not ena-
bled on screen 43.
It is not a blocking alarm, but only a signal that appears at the end of
brewing or auto levelling.
It disappears after 5 seconds.
Possible water leak signalling screen.
This appears if the counter detects an impulse count for at least 5
seconds when brewing or loading for self-levelling is not in progress.
This screen will not be displayed if the water counter was not ena-
bled on screen 43.
The signal disappears after 10 seconds and reappears after one minute
unless there the machine is brewing or auto levelling, in which case the
signal appears only after completing brewing or auto levelling.
65