Connect the power cord to the electrical mains as shown in the attached diagram:
ONLy fOR
MODELS
TOP 85 SPRINT
REMAINING
MODELS
NOTES:
* The power absorbed
by the electric heating
elements can be
reduced to 2/3 by
eliminating one of the
black wires.
3.7 Connection to the equipotential clamp
The machine is provided with an equipotential clamp placed under the tray and the bottom support
cup grid.
The terminal is identified by the equipotential symbol reported here on the side.
Connect only cables of 2.5 mm to 6 mm with ring lugs for screw M8
The connection to the equipotential clamp must be performed by LA SAN MARCO SPA authori-
zed qualified personnel.
48
230V MONO-PhASE
BLUE
BLACk
GREy
BROWN
yE/GR
400V-3 TRI-PhASE
BLUE
BLACk
GREy
BROWN
yE/GR
230V-3 TRI-PhASE
BLUE
BLACk
GREy
BROWN
yE/GR
230V MONO-PhASE*
400V-3N TRI-PhASE
BLUE
BLUE
BLACk
BLACk
GREy
GREy
BROWN
BROWN
yE/GR
yE/GR
230V-3 TRI-PhASE
BLUE
BLACk
GREy
BROWN
yE/GR
To make the connection remove the bottom tray. On the left side of the frame,
indicated by the equipotential symbol, there is the screw-clamp to be used to
connect a cable of 2.5 mm to 6 mm with ring lugs for screw M8.
2 hEATING ELEMENTS
BLACk
GREy
BROWN
BLUE
yE/GR
3 hEATING ELEMENTS
BLUE
BLACk
BROWN
GREy
yE/GR
3 hEATING ELEMENTS
BLUE
BLACk
BROWN
GREy
yE/GR
3 hEATING ELEMENTS
BLUE
BLACk
GRIGIO
BROWN
yE/GR
3 hEATING ELEMENTS
BLUE
BLACk
BROWN
GREy
yE/GR