Backwash

Can be set as a single speed or alternatively set two speeds and the pump speed will "pulse" between the
two settings. Minimum speed can be set between 1-10, maximum speed can only be set between 5-10.

External time present

Swipe this on or off, depending on whether you are using an external timer/chlorinator.

Disconnect function

The "disconnect from pump" function can be used to:
• Allow another device to control the pump;
• Disconnect so that you will not automatically connect to the pump;
• Please note that the Bluetooth connection will automatically disconnect after a minute of no communication.

Factory reset

This will reset the pump back to factory configurations and allows you to start the setup process again.
• Select "reset pump";
• Turn dial to "off" position, then turn dial to "Bluetooth";
• You can then re-pair with your phone. This procedure is in place so that the pump cannot accidentally be reset.

Pump fault finding

In the instance that there is a fault, the following screen will appear, with text description below the fault
indicating how to remedy.
SilensorPro BT
Fault title
Pump fault – overcurrent
Pump fault – under voltage
Pump fault – over temperature
Pump fault – motor stalled
Pump fault – underload/loss of prime
Fault description
Check that the motor can rotate freely. Unplug for 1
minute and plug back in to reset. If problem persists call
Davey, or an authorised repair agent.
Supply voltage issue. When power is back to normal,
unplug for 1 minute and plug back in to reset.
Pump is too hot. Check the ambient temperature. Set to
lowest speed possible if ambient temperature is too high.
Check that the motor can rotate freely. Unplug for 1
minute and plug back in to reset.
Check if there's enough water inside the pump. Unplug for
1 minute and plug back in to reset. If problem persists call
Davey, or an authorised repair agent.