Setting time and date:
The flashing digit indicates the day of the
week: press the
and
sired day, press
MODE to confirm.
Use the
and
keys to set the hour and
then
MODE to advance to the minutes
setting.
Repeat the same procedure to set the min-
utes. Press
MODE to confirm.
Setting the weekly program.
The programming starts automatically from
day 1; to set the hour, use the
key sets the Comfort temperature,
The
which is indicated by full bar; the
the Night, which is indicated by an empty bar.
In order to program the 24 hours, press the
and
keys: once one of the two keys has
been pressed, the program will advance auto-
matically to the following hour.
• Key
and key
mode on for both.
• Key
with blue light flashing and key
with blue light on: mode that indicates 1°C
less than the temperature set.
• Key
and key
mode on standby for both.
Example:
Appuyez sur la touche
firmer et avancer vers le jour suivant.
Lorsque le 7
jour est configuré, le pro-
ème
gramme revient automatiquement au mode
de fonctionnement précédent.
Antifrost mode
The Antifrost mode enables the heating
element of the electronic control when the
room temperature drops below a specific
threshold (please refer to the thermostat
user manual).
It is recommended to use this mode when
the room is not occupied for several days.
• Press the
MODE key until this mode is
selected.
keys to set the de-
and
keys.
key sets
with blue light on:
with blue light flashing:
MODE pour con-
[ 32 - EN ]
Boost 2h mode
The Boost 2h mode can be used to heat
quickly the room.
• To enable the function, press the relative
BOOST 2h key. For safety reasons, the
ambient temperature may never exceed
30°C, and so a safety control mechanism
prevents this happening. When the time ex-
pires, the control goes back to the operat-
ing mode set before going into boost mode
for 2 hours. The user can exit this mode by
pressing the
BOOST key.
• Key
and key
mode on for both.
• Key
with blue light flashing and key
with blue light on: mode that indicates 1°C
less than the temperature set.
• Key
and key
mode on standby for both.
Fil-pilote
Only for units that have this mode.
In PILOT WIRE mode the unit is controlled
by a signal from a dedicated control unit, that
sets for operating mode for all the connected
thermostats. The only input required in this
mode is the required COMFORT tempera-
ture, which is set by pushing the [+] and [-]
keys.
In this mode one of 6 different signals may
be detected, which correspond to the same
number of operating modes:
1.
STANDBY: the heating element remains
switched off, but the thermostat is kept
switched on.
2.
COMFORT: the COMFORT tempera-
ture set by the user, is kept constant in
the room, by switching the heating ele-
ment on and off in an intelligent manner.
3.
ECO: a temperature is maintained that is
always 3,5°C lower than the COMFORT
temperature.
4.
ANTI-FREEZE: the ambient temperature
is always kept above 7°C to avoid freez-
ing.
5.
COMFORT-1: the ambient temperature
is kept 1°C lower than the COMFORT
temperature.
with blue light on:
with blue light flashing: