3.
fresh air hose breathing apparatuses;
4.
powered respirators, only if they are made up of mask, power unit and
filters, which have been appropriately tested and certified in compliance
with the EN norms in force;
5.
by using a connector (reference number 4338.3220), the halfmasks can be
also used with 230 series, gas, particle and combined filters.
EN
4
The use of POLIMASK halfmasks in combination with filters is allowed only ac-
cording to the following conditions:
4.1
The use of POLIMASK halfmasks in combination with gas filters is allowed only
up to a concentration of contaminant which is equal to 30 times the threshold
limit values (TLV). On condition that it is not used in presence of gas concen-
trations higher than those which have been set for gas filters (see instructions
for use of filters). The use of POLIMASK half masks is allowed with gas filter of
class 1 and 2.
Gas filter class
Maximum concentration 0,1 Vol.% or 1000 ppm 0,5 Vol.% or 5000 ppm 1. Vol.% or 10000 ppm
4.2
For the use of particle filters with POLIMASK, the following multiples of the th-
reshold limit values (TLV) are equal to the maximum concentration of contami-
nant permitted in the ambient atmosphere. For higher concentrations of toxic
particles use full-face masks. if necessary use isolating breathing apparatuses.
Particle filter class
Multiple of the
threshold values
Observations - Limi-
tations
4.3
When using the combined filters, both the limitations for use above indicated
are to be observed. The threshold limit values, indicated in the table, equal to
the highest concentration of toxic substance (gas or dusts) permitted in the sur-
rounding environment.
Limitations for use
With gas filters
With particle filters
not suitable for pro-
tection against liquid
aerosols, radioactive and
cancerogenic substances,
microorganisms and
active biochemical
substances
With combined filter
1
P1
4
not suitable for protec-
tion against radioactive
substances, micro-
organisms (bacteria,
fungi and moulds),
active biochemical
substances (enzymes,
20
2
P2
10
protection against
radioactive substances,
microorganisms and
active biochemical
hormones)
3
P3
30
not suitable for
substances