Starmix ISP iPulse AR P-1435 Notice D'utilisation page 24

Table des Matières

Publicité

▷ Place the upper section on the container and close the side
latches.
(* depending on the equipment variant)
5.4 Insert PE emptying and disposal bag*
Only the vacuum cleaners class M and H with special containers
and rotary slider in the suction aperture of types ISP iPulse ARM,
ISP iPulse ARH and ISP iPulse ARH-Asbestos are suitable for
the use of PE Emptying and disposal bags.
Operating the rotary slider*
▶ Push the rotary slider* from the inside to the outside, turn
through 180° (see mark) and then push inwards again from
the outside through the suction spigot
▶ Place the rotary slider* in the suction aperture with the mark ●
pointing upwards.
▷ Slide the lange completely over the suction aperture and place
the upper bag opening over the edge of the container.
▷ Place the upper section on the container and close the side
latches.
(* depending on the equipment variant)
6 Changing the ilter
6.1 Changing the folding ilter
(See short-form instructions
▷ Shake the folding ilter cassettes before changing them.
24 - GB
NOTE
NOTE
)
▷ Turn the lock on the latch through 90° in a counter-clockwise
direction with a coin or similar object and push the latch to the
rear.
▷ Fold the hood up
▷ Immediately isolate the folding ilter cassettes that you have
removed in a dust-tight plastic bag and dispose of properly in
accordance with the stipulations.
▷ Insert new folding ilter cassettes.
▷ Lift the locking bracket up, fold the hood down and click in place
with light pressure.
7 Changing the motor protection ilter
(See short-form instructions
If the motor protection ilter is contaminated this indicates defec-
tive ilter cassettes.
▷ Replacing the folding ilter cassettes.
▷ Replace the motor protection ilter or wash the motor
protection ilter under lowing water, dry and re-insert..
8 Transport
▷ Insert the closing plug* of the vacuum cleaner into the suction
aperture.
▷ The motor head must be securely ixed to the container (close
the latches).
▷ Place the accessories in a suitable plastic bag and seal the plas-
tic bag or place it in the tool storage compartment.
▷ Plug the ends of the suction hose into each other.
▷ Place the hose around the vacuum cleaner and clamp onto the
handle (see short-form instructions).
9 Maintenance
Switch the vacuum cleaner off and pull out the mains plug before
any maintenance work.
For maintenance by the user, the vacuum cleaner must be
- dismantled,
- cleaned and
- maintained,
as far as possible without creating any danger to the maintenance
personnel or other.
Precautionary measures
Suitable precautionary measures include
- Cleaning before dismantling,
- Provide local iltered positive ventilation where the vacuum
cleaner is to be dismantled,
- Clean the maintenance area and
- suitable personal protection equipment.
Precautionary measures with vacuum cleaners class H and M
The outside of the vacuum cleaner should be cleaned and wiped
down or should be treated with a sealing agent before being
)
NOTE