Mounting and securing
Mark out and drill fixing holes for door closer and guide rail using fitting template or cut M5 thread
X
if necessary.
6.2
Mount guide rail and end caps
Align spacers on moving and fixed-leaf guide rails (1.).
X
Fix guide rails in place (tightening torque: 2 Nm) (2.).
X
Align end caps on moving leaf and screw on (3.) (tightening torque: 2 Nm).
X
Slide on cover at fixed leaf (4.)
X
Mount door closer and sliding lever according to the mounting instructions (5.).
X
All screwing torques are to be adjusted on site, if necessary.
6.3
Connecting wire cable to trigger
Unscrew set screw and lock nut 12 mm at clamping part (1.).
X
Suspend ball on wire cable in the trigger lever (2.).
X
Guide wire cable into funnel (3.).
X
Thread clamping part onto wire cable (4.).
X
Insert clamping part and thread wire cable through oblong hole (5.).
X
Push wire cable redirection onto wire cable (6.).