Télécharger Imprimer la page

Battery Charging; Lithium Batteries (Lipo, Life And Li-Ion) - Team Orion Advantage IQ605 Manuel D'utilisation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
The charger has default settings, which are compatible with the most popular batteries. If you wish to
change the default settings please go to p.13 of these instructions.
From the program select screen, use the STOP or - keys to select LiPo battery type and then press
the START key.
PROGRAM SELECT
LiPo BATT
LiPo CHARGE
5.0A 7.4V(2S)
By pressing the + and - keys, you can select the different function modes:
LiPo CHARGE
Normal charge without balancing
LiPo BALANCE
Balance charge using the integrated balancer
LiPo FAST CHG
Fast charge without balancing and less accurate
LiPo STORAGE
Storage charge or discharge (to 50% of capacity)
LiPo DISCHARGE
Discharge of the battery
For increased safety, we recommend you always use the balance charge!
 Modifying the settings
Press the START key so that the charge/discharge current or battery voltage (cell count) setting blinks.
Use the + and - keys to adjust the charge or discharge current (0.1 – 1A or 0.1 - 5A) or the cell count
(1S to 6S).
For the charge and fast charge modes there is also an AUTO setting, which detects the battery voltage
automatically.
www.teamorion.com

Battery charging

Lithium batteries (LiPo, LiFe and Li-Ion)

7

Publicité

loading

Ce manuel est également adapté pour:

Ori30154Ori30155Ori30156Ori30157Ori30161