Technical Data/Trouble Shooting - Hansgrohe PHARO Duschtempel 115 EL 40 29040 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

T e c h n i c a l d a t a / a i d
Flow diagram
1
Q l/sec
l/min
1 Overhead shower
2 Overhead shower and body showers
From
the function is guaranted, the ideal spray
pattern will be reached from 2.0 bar pressure
Trouble shooting
Failure
No function
Light fails
One halogen spotlight fails
No water flow when using
the shower
2
Possible Cause
No current available
Transformer defect
Connection to the lighting is
interupted
Halogen spotlight defect
Floor shut-off device is
closed
Shut-off valve (Thermostat)
is closed
Filters are polluted
Mains supply:
Rated output:
Transformer:
Protection Type:
Minimum water pressure:
Applied pressure:
Recommended pressure:
Test pressure:
Hot water temperature:
Recommended hot water
temperature:
Cold water temperature:
Environmental temperature range:
Temperature block:
Humidity :
Flow rate at 3 bar pressure
Overhead shower:
Hand shower:
Body shower:
Hand shower + Body shower:
Overhead shower + Hand shower
Overhead shower +Body shower
N. B. Flow rate will differ then using a pump
Remedy
Check current conductor
Replace transformer, contact manufacturer service
Plug in the connector of the lights
Replace halogen bulb (12 V/ 10 Watt)
Open floor shut-off device
Open shut-off valve
Clean filter (Servicing thermostat)
230V~ 60/50Hz
max. 2,5A
Protection class II
IP 65
1,5 bar
max.10 bar
2 - 5 bar
10 bar
max. 70° C
60° C
min. 4°C
10°C - 45°C
38°C
Ensure that none of
the electronic com-
ponents are expo-
sed to humidity
17l/min
10l/min
15l/min
19l/min
20l/min
22l/min
51