8.4 Replacing the stripping blades

Potential risk of fatality due to electric
shock
When working on the inside of the machine,
non-insulated parts may be touched.
► Switch the machine off.
► Pull out the power plug.
► Open the front plate and place it down
carefully.
Risk of injury posed by sharp blades
► Use forceps to change the blades.
► Dispose of the removed blades in a sepa-
rate container.
All present blades must be replaced each time
the knife is changed.
► Loosen the fixing screws (1).
► Remove the blades mount (2).
► Observe the installation position.
► Turn the stripping blades or replace of the existing
blades with new ones.
► Reinsert the blades mount.
► Fasten the fixing screws.
1
2
Figure 8.1
Stripping blades for the Power Stripper 6.0, Power Strip-
per 16
2562260000/01/10.2017
WARNING
CAUTION
1
2
Figure 8.2
Stripping blades for the Power Stripper auto

8.5 Replacing the fuses

► Make sure that the machine is switched off.
► Remove the power plug.
Figure 8.3
Opening the fuse compartment
► Lever the fuse compartment (1) out of the mains filter
unit using a slotted screwdriver.
► Replace both fuses with new ones (2 x T2AH250V).
► Put the fuse compartment back into the mains filter unit.
Troubleshooting