4) Programming

All the functions described in the "Programmable functions" chapter
can be selected by means of a programming phase which
terminates by memorising the choices made.
4.1) Delete memory
Each new programme replaces the previous settings, normally it is
not necessary to "delete all" the memory.
If required, the memory can be totally deleted by performing this
simple operation:
Table "A1"
Delete memory:
1.
Disconnect the power supply
2.
Press and hold down buttons P1 and P2 on the card
3.
Connect the power supply
4.
Wait for at least 3 seconds before releasing the two keys
N.B.: if the memory was deleted correctly, all the Leds will switch off for 1 second.

4.2) Programming methods

Just the two P1 and P2 buttons on the card are used for all
programming phases
In this case, the 5 "INPUT" Leds normally indicating the status of the
inputs show the selected "parameter".
Example:
1
2
3
4
5
Level 1:
Led 1
"Automatic"
function
Level 2:
Parameter:
Pause time
Led 1 : 5s
Led 2 : 10s
Led 3 : 20s
Led 4 : 40s
Led 5 : 80s
10
In
this
"Automatic",
flashing and motor M1
opening delay functions
P1
P2
are active.
Led 2
"Condominium"
function
Parameter:
AUX input
Led 1 : Type 1 partial opening Led 1 : 2s
Led 2 : Type 2 partial opening Led 2 : 4s
Led 3 : Open only
Led 4 : Close only
Led 5 : Photo 2
Leds off:
input disabled
The control unit therefore has a memory which stores the functions
and parameters relative to the automation process.
!
After deleting the memory, a new search must be
made for the mechanical stops, while all the functions
return to their pre-set values.
There are two different programming levels:
• At level 1, the functions can be activated or deactivated. Each
INPUT Led corresponds to a function: if the Led is on, the function
is active; if it is off, it is deactivated.
Led 1 : "Automatic" function
Led 2 : "Condominium" function
Led 3 : Pre-flashing
Led 4 : Close after photo
case
the
Led 5 : Opening delay
the
pre-
• It is possible to switch from level 1 to level 2 where the function
parameters can be chosen, each Led corresponds to a different
value to associate with the parameter.
Led 3
Pre-flashing
Parameter:
Pre-flashing time
Led 3 : 6s
Led 4 : 8s
Led 5 : 10s
Led 4
Close 4 seconds
after photo
Parameter:
Parameter:
Current
Delay
sensitivity
Led 1 : Level 1
Led 2 : Level 2
Led 3 : Level 3
Led 4 : Level 4
Led 5 : Level 5
Leds off:
current sensitivity disabled
Level 1 = most sensitive
Level 5 = least sensitive
Example
P1
P2
P1
P2
3s
Led 5
Opening delay
Led 1 : 2s
Led 2 : 4s
Led 3 : 6s
Led 4 : 8s
Led 5 : 10s