5 Settings
Rang
Status
e
34
GradLevel2PowerCtrl
35
GradLevel3PowerCtrl
36
ProtectFlamePwrCtrl
37
StabilizationTime
38
ColdStart
39
ChResume
40
SuRemoveBurner
41
FanToPostPurge
44
StopFan
45
LimitedPwrOnTflueGas
48
Reduced Set Point
60
PumpPostRunning
61
OpenPump
63
SetAntiCycleTimer
105
Calibration
200
Initialising Done
201
Initialising Csu
202
Init. Identifiers
203
Init.BL.Parameter
204
Init. Safety Unit
205
Init. Blocking
254
StateUnknown
255
SuOutOfResetsWait1Hr
86
Explanation
The modulation is set to low load due to a faster heat
exchanger temperature change than gradient level 2.
The appliance is in blocking mode due to a faster heat
exchanger temperature change than gradient level 1.
The burner power is increased due to a low ionisation
signal.
The appliance is in stabilisation time. Temperatures
should stabilise and temperature protections are
switched off.
The appliance runs at start load to prevent cold start
noise.
The appliance resumes central heating after a domes
tic hot water interruption.
Burner demand is removed from safety core.
The fan runs to purge the heat exchanger after the ap
pliance stopped.
The fan has stopped.
The power of the appliance is decreased to lower the
flue gas temperature.
The desired flow temperature is reduced to protect the
heat exchanger.
The pump is active after the appliance stopped in or
der to bring the remaining heat into the system.
The pump has stopped.
-
The electronic combustion process calibrates the
combustion.
Initialisation is finished.
The CSU is initialising.
The identifiers are initialising.
The blocking parameters are initialising.
The safety unit is initialising.
The blocking is initialising.
The sub state is undefined.
The safety unit is blocking due to too many resets.
Wait for 60 minutes or turn the power off and on
again.
7747028 - v.01 - 25112019