7.2
INSTALLATION METHOD
• Fix the bracket to the wall using a box 503 and the screws provided or a Ø 60 mm box with suitable screws.
• Program the dip-switches and connect the system wires to the terminal boards.
• Couple the video door phone to the bracket at the four hooks on the sides.
• Remove the protective fi lm from the display.
2 M3.5 x 19 mm
provided
2
2
Remove the protective fi lm from the video door phone display.
7.3
TERMINAL BOARD DESCRIPTION
Terminal board
1
2
DS1723-050B
1
Terminal name
LI
LI
LO
LO
LP
LP
FC
FC
0
C
AL
AL
Box
503
2 2.9 x 13 mm
countersunk screws
1
Bus input (LINE IN)
Bus output (LINE OUT)
24V~ local power
Floor call
Supplementary ringer (output relay 1 – OP5 / OP5A)
Alarm sensor input
Box
Ø 60 mm
3
Description
33