9. WORKING ELECTRONICAL CONTROL
5
6
7
8
6
7
1
2
1.▲ : to raise temperature OR searching choice
2.▼: to lower the temperature OR searching choice
3. FNC to return to previous screen
4. SET to make a choice or confirm
5. light is burning: compressor is running
blinking: compressor in waiting time
6. light is burning: ventilator inside is running
blinking: ventilator inside in waiting time
7. burning: automatic defrosting is running
blinking: manuel defrosting is running
During cooling the compressor is running (9) + ventilator outside (1).
When the cooling battery is cooled, the ventilators inside are running(12).
→ control light 5 and 6 are burning
During defrosting the compressor is running (9) and the ventilator outside(1).
→ control light 5 and 7 are burning