5. TECHNICAL SPECIFICATIONS
Cooling capacity: 1100 Watt
Cool medium: 450 gr R410A (= 1 ton CO
-eq)
2
This coolunit contains fluorinated greenhouse gases covered by the Kyoto
Protocol.
Measured electrical power: 550 Watt
Electrical power: 220V +/-10% mono - 50Hz - 2,7A
Measurement: B x D x H: 820x490x800mm
Conform CE
Guarantee:
3 years complete guarantee except on the vaporisor ventilators inside.(1 year)
The guarantee expires in case of bad use or bad maintenance.
6. ASSEMBLAGE
Place the cooling unit on the opening of the cooling box .
After that, lute the slit with silicone.
Put the connector in a fix mounted socket which is fused with an automat and
loss power switch as described in the norms.
It's forbidden to connect the cooling device with extension cables or on each
other manner than described above.
There is a possibility to connect a door switch on the connectors 5 and 6 on the
electronic controller. (door closed = open contact)
ENGLISH
29