CleverLevel
Adaptive trigger – hygienic/industrial
Power supply
Voltage supply
Reverse polarity
protection
Current consumption
(without load)
Power-up time
Features
Repeatability
Hysteresis
Response time
Damping
Operating conditions
Ordering key Process connection
G070
G 1/2 A ISO 228-1 BSC G07
A030
G1/2 A hygienic
G510
G 1/2 A DIN 3852-E
N020
1/2-14 NPT
A031
G1/2 A hygienic,
length 82 mm
G1/2 A hygienic,
A032
adjustable connection
12 / 44
Level measurement
®
PL20H/S
8 ... 35 V DC
Yes
25 mA typ.,
53 mA max.
< 1.5 s
± 1 mm
± 1 mm
< 150 ms
0.1 ... 10.0 s
(adjustable)
BCID
A03
G51
N02
A03
A03
Operating Instructions
Output signal
Output type
Current load
Short circuit
protection
Voltage drop
Leakage current
Switching logic
Continuous
Process
Process
temperature
pressure
at
T
< 50 °C
amb
[°C]
[bar]
–40 ... 115
–1 ... 100
–40 ... 115
–1 ... 10
–40 ... 115
–1 ... 100
–40 ... 115
–1 ... 100
–40 ... 115
–1 ... 100
–40 ... 150
–1 ... 5
PNP
NPN
Digital (push-pull)
4 ... 20 mA
100 mA max.
Yes
PNP: (+Vs –1.4 V) ± 0.5 V,
Rload = 10 kΩ
NPN: (–Vs +0.6 V) ± 0.3 V,
Rload = 10 kΩ
± 100 μA max.
Normally open (NO), active
low
Normally closed (NC),
active high
Temporary (t < 1 h)
Max.
Process
process
pressure
tempera-
at max.
ture at
process
T
< 50 °C
temperature
amb
[°C]
[bar]
135
–1 ... 100
135
–1 ... 5
135
–1 ... 100
135
–1 ... 100
135
–1 ... 100
N/A
N/A
www.baumer.com