Télécharger Imprimer la page

Kratki LUCY 12 SLIM Mode D'emploi page 53

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
Safety devices
Pressure switch: monitors
depression in the smoke duct.
It is designed to shut down
the pellet feed screw in the
event of an obstructed fl ue or
signifi cant back-pressure in
the presence of wind. At the
time of the pressure switch will
show "A LAR ‐DE P‐ FAIL".
Electrical safety: the stove
is protected against violent
surges of current (ex. lightnings)
by the main fuse 4 A which is
located on the control panel
at the rear of the Stove. Other
fuses to protect the electronic
boards are to be found on the
boards themselves.
Tampering with the safety devices is prohibited. It is only after eliminating
the cause which gave rise to the intervention of the safety system, that it is
possible to relight the stove and thus reset the automatic operation of the
sensor. To understand which anomaly has occurred, consult this manual at
paragraph relating to alarms which explains what to do based on the alarm
message the stove display.
Reduction motor: if the motor
stops, the Stove continues to
function until the fl ame goes
out for lack of fuel, and until
It has cooled down to the
minimum level.
RESTART
PELLET
Pellets temperature safety:
In the rare event there is a too
high temperature in the tank,
the
thermostat
for
pellets
safety
with
manual
creates an alarm "AL AR‐ S IC ‐
FAI L " stopping the pellet boiler
stove. You
need to reset the system
working on the device placed
on the back of the Stove.
Flue gas temperature sensor:
thermocouple that measures
the temperature of the fumes
while keeping the operation or
shuts the Stove when the fl ue
gas temperature drops below
the preset value.
Room thermostat: the room
thermostat detects the present
temperature in the room. When
it detects the set temperature
reset
on the display, the stove will
go into operation in ECO ie
hold function to save fuel.
The
should be spread so as not
to be conditioned by the
temperature of the body stove.
room
thermostat
53