The chimney cap
The chimney cap must respect the following requirements:
• It must have the equivalent diameter and internal form
of the fl ue.
• It must have a useful outlet diameter of not less than
double that of the fl ue.
• The chimney cap on the roof or that remains in contact
with the outside (for example, in case of open lofts or
attics), must be covered with elements in brick or tile
and must, in any case, be well insulated.
• It must be constructed to prevent rain, snow, and
extraneous bodies from entering the fl ue and so that
the discharge of the products of combustion is not
inhibited by wind from any quarter or strength (wind-
proof chimney cap).
• The chimney cap must be positioned in such a way as
to guarantee the adequate dispersion and dilution of the
products of combustion and in any case, must be out of
the refl ux zone. This zone has different dimensions and
forms according to the angle of inclination of the roof so
it is necessary to adopt minimum heights.
• The chimney cap must be a wind-proof type and must
be above the ridge.
• Eventual structures or other obstacles that are higher
than the chimney cap must not be too close to the
chimney cap itself.
• The device should not be installed in the fl ue shared.
YES
Caratteristiche del comignolo
Distance to objects
It is also recommended to keep the pellets and all
fl ammable materials at a suitable distance from the stove.
20 cm
42
NO
5 cm
100 cm
Minimum aeration for comburant air intake
The combustion air must be taken from the outdoor
ambience absolutely.
For a correct and safe placement of the air intake all the
measures and prescriptions must be respected. There are
distances to respect to prevent the comburant air from
being subtracted from another source: for example the
opening of a window could cause eddies in the outside air
subtracting it from the stove.
Installation of wall plug and fi xing the bracket onto
the wall
For safety reasons, it is mandatory to
anchor the heater with the special guide
directly to the supporting wall.
To ensure the installation at the right distance from the
wall, it has been inserted, in series, an aluminium guide,
having an end key and the other an end ring. The end key
is inserted into the special slot provided on the heater rear.
The end ring is instead fi xed to the wall. In this way, the
heater will be perfectly fi xed to the closest surface to
ensure a perfect stability and the right anchoring at the
safety distance.
REMARKS:
- the appliance must be installed by a qualifi ed technician in
possession of the technical and professional requirements
according to the DM37/2008 that, under its responsibility,
to ensure compliance with the rules of good technique.
- you need to keep in mind all laws and national, regional,
provincial and municipal laws of the country in which you
installed the device
- check that the fl oor is not fl ammable: if necessary use a
suitable platform
- in the room where the generator must be installed to
heat must not pre-exist or be installed with an extractor
hood or ventilation ducts of the collective type.
Should these devices be located in adjacent rooms
communicating with the installation, and 'prohibited the
simultaneous use of the heat generator, where there is a
risk that one of the two rooms being placed in depression
than the other
- it is not permissible to install in bedrooms or bathrooms.