Paramètres : 9-** Profibus - Danfoss VLT Guide De Programmation

Automationdrive
Masquer les pouces Voir aussi pour VLT:
Table des Matières

Publicité

Description des paramètres
3.11 Paramètres : 9-** Profibus
9-00 Setpoint
Range:
0
[0 -
*
3
3
65535 ]
9-07 Actual Value
Range:
0
[0 - 65535 ] Ce paramètre fournit la valeur effective
*
9-15 PCD Write Configuration
Tableau [10]
Option:
[0]
None
*
[302]
Minimum Reference
[303]
Maximum Reference
[312]
Catch up/slow Down Value
[341]
Ramp 1 Ramp up Time
[342]
Ramp 1 Ramp Down Time
[351]
Ramp 2 Ramp up Time
[352]
Ramp 2 Ramp down Time
[380]
Jog Ramp Time
[381]
Quick Stop Ramp Time
[411]
Motor Speed Low Limit [RPM]
[412]
Motor Speed Low Limit [Hz]
[413]
Motor Speed High Limit [RPM]
[414]
Motor Speed High Limit [Hz]
[416]
Torque Limit Motor Mode
[417]
Torque Limit Generator Mode
[590]
Digital & Relay Bus Control
[593]
Pulse Out #27 Bus Control
[595]
Pulse Out #29 Bus Control
114
Guide de programmation du FC 300
Fonction:
Ce paramètre reçoit une référence cyclique d'un
maître classe 2. Si la priorité de contrôle est
réglée sur le maître de classe 2, la référence
pour le variateur de fréquence est extraite de
ce par., tandis que la référence cyclique sera
ignorée.
Fonction:
principale (MAV) du maître classe 2. Il est
valide si la priorité de contrôle est réglée sur
maître classe 2.
Fonction:
Sélectionner les par. à
attribuer aux PCD 3 à 10
des télégrammes. Nombre
de PCD disponibles en
fonction du type de
télégramme. Les valeurs
contenues dans les PCD 3
à 10 sont ensuite inscrites
dans les paramètres
sélectionnés sous forme
de valeurs de données.
On peut, par ailleurs,
spécifier un télégramme
Profibus standard dans le
9-22 Telegram Selection.
MG33MD04 - VLT
9-15 PCD Write Configuration
Tableau [10]
Option:
[597]
Pulse Out #X30/6 Bus Control
[653]
Term 42 Output Bus Ctrl
[663]
Terminal X30/8 Bus Control
[673]
Terminal X45/1 Bus Control
[683]
Terminal X45/3 Bus Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1680] Fieldbus CTW 1
[1682] Fieldbus REF 1
[1685] FC Port CTW 1
[1686] FC Port REF 1
[3310] Sync Factor Master
[3311] Sync Factor Slave
[3401] PCD 1 Write to MCO
[3402] PCD 2 Write to MCO
[3403] PCD 3 Write to MCO
[3404] PCD 4 Write to MCO
[3405] PCD 5 Write to MCO
[3406] PCD 6 Write to MCO
[3407] PCD 7 Write to MCO
[3408] PCD 8 Write to MCO
[3409] PCD 9 Write to MCO
[3410] PCD 10 Write to MCO
9-16 PCD Read Configuration
Tableau [10]
Option:
[0]
None
*
[15]
Readout: actual setup
[1472] Legacy Alarm Word
[1473] Legacy Warning Word
[1474] Leg. Ext. Status Word
[1500] Operating Hours
[1501] Running Hours
[1502] kWh Counter
[1600] Control Word
[1601] Reference [Unit]
[1602] Reference %
[1603] Status Word
®
est une marque déposée Danfoss
Fonction:
Fonction:
Sélectionner les par. à
attribuer aux PCD 3 à 10 des
télégrammes. Nombre de
PCD disponibles en fonction
du type de télégramme. Les
PCD 3 à 10 contiennent les
valeurs réelles des paramètres
sélectionnés. Pour des
télégrammes standard
Profibus, voir le 9-22 Telegram
Selection.