Switch off appliance.
Minimize the air supply on the stove.
Allow the chimney to burn out in a controlled man-
ner.
Have the cause investigated by specialised person-
nel.
Power failure or
longer switch-off of the main switch
In the event of power failure or longer switch-off of the
main switch, the controller saves important combus-
tion-related data and settings.
When the appliance is again supplied with power it will
be regulated to the operating status prior to the pow-
er failure.
If the appliance is not supplied with power for longer
than 14 days, date and time must be reset. The con-
troller recognises this and automatically changes to the
"date & time" menu after switching on.

Recommissioning

After longer operating interruptions you must check
for unhindered extraction of waste gas.
Prior to switching on, check and if necessary top up
the pellet tank.
Prior to each start, subject the combustion pan to a
visual inspection and clean it if necessary. Ensure
that pellets are not manually placed in the combus-
tion pan.

Cladding

The natural stone cladding is manufactured from a
"natural" block of stone, consequently the structure
and the colouration can be very different.
The surface can change due to temperature.