Installation of the stove
even and horizontal. The stove must only be installed
combustible spark protection plate must be used. This
spark protection plate must project beyond the com-
bustion chamber opening of the stove, 50 cm to the
front and 30 cm to the side.
A protective panel is not required under the stove and
under the waste gas pipe.
95 mm
1
2
Fig.1
1 Main switch
2 Combustion air duct
3 Room temperature sensor
4 Socket for the connection plug
5 Connecting cable
6 Connection duct - waste air pipe
40
3 4
5
6
Installation sequence
Determine the installation location. Objects made
be placed in the radiation area of the wood-burn-
-
ing stove to a distance of 80 cm, measured from the
view pane of the combustion chamber door.
Depending on the installation position of the stove in
or load-bearing), the following distances from walls
need to be observed in accordance with the position
of the combustion chamber door to the wall / side
panel or the back panel (see schematic diagram).
When not dealing with walls that need to be protect-
ed, you merely need to observe a minimum distance
of approx. 5 cm to allow for proper heat
5
Stove installed straight in corner
5
Stove installed diagonally in corner
dissipation..
5
Dimensions in cm
Dimensions in cm