Error messages

While an error is present a running combustion process will be stopped. If an error message occurs in idle status,
The display can only be exited with (ESC) when the cause of the error has been eliminated.
If necessary request a service technician.
Display
60
Possible cause of error
Pellet tank may be empty.
Combustion pan contaminated.
Combustion chamber door was open
too long.
Chimney is blocked.
Glass pane is defective.
Ash box is not installed correctly.
Induced draught fan and / or speed
monitor defective or not connected.
Flame temperature sensor defective or
not connected.
Room temperature sensor defective or
not connected.
One of the safety elements (safety tem-
perature limiter or inclination switch) has
tripped.
Flame temperature has dropped unex-
pectedly.
Possible elimination
Fill the pellet tank.
Clean combustion pan.
Close combustion chamber door.
Check chimney.
Check glass pane.
Push in ash box and lock.
Request a service technician.
Request a service technician.
Request a service technician.
Request a service technician.
Fill the pellet tank.