Regulations to be observed
Local and statutory building regulations.
The stove must be set up and connected to the
lations must be complied with for safe installation of
the connecting piece.
Installation and connection of electrical appliances
A regular inspection of the stove must be executed
by a specialist.
Chimney dimensioning
The chimney is dimensioned in accordance with
DIN EN 13384-2 or in accordance with country-specif-
ic regulations.
Rated heat output
Partial heat output
Waste air temperature at
connection duct
Minimum delivery pressure
at rated heat output
Minimum delivery pressure
at partial heat output
At excessive delivery pressures >20 Pa a delivery
pressure limitation element must be implemented (e.g.
secondary air regulator in the chimney).
For the chimney calculation the required delivery pres-
sure at the waste air duct must be set to 0 Pa.
permission. Speak with your district master chimney
sweep.
Combustion air supply
available for the stove. The cross section of the com-
-
bustion air line must not underrange D=80 mm.
External combustion air connection
By an external operating mode, the combustion air
can be added from outside through a leak-proof line or
through a supply duct in the chimney. Thus, speak with
your district chimney sweep master.
Due to energy saving reasons, the combustion air in-
let should be able to be blocked if the stove is not being
operated. This can occur through a shut-off valve in the
combustion air line or through the air slide valves on
the stove. If a shut-off valve is used, this must be clear-
6,0 kW
Through the shutoff, it is avoided that heat is removed
2,1 kW
from the set-up room through the constant circulation
of cold combustion air and cold combustion air lines
5,6 g/s
may lead to an increased formation of condensation.
128 °C
We recommend the motorized combustion air damp-
er from the Olsberg assortment, article number
43/1481.9240, which automatically opens and closes
12 Pa
with switch on and off the heating.
11 Pa
the stove.
Attention:
The combustion air line must not be sealed in op-
eration!
In order to supply the appliance with combustion air
via a line and not from the installation room, a combus-
tion air line Ø 80 mm must be attached either on the
rear or on the bottom of the appliance. At extremely
low outdoor temperatures, condensation can occur on
the combustion air line. For this reason it must be in-
sulated with a suitable insulating material. Comply with
the technical rules of the Association of Tiled Stove and
Hot-Air Heating System Builders.
We recommend the combustion air pipes with sealing
lip from the Olsberg assortment.
Attention:
Appliances with external combustion air connec-
tion are not suitable for concurrent operation with
ventilation systems, without a supplemental safe-
ty system.
39